TABLE OF CONTENTS:
Fantuzzi Liftruck V 2.5 FAULT CODE MANUAL – PDF DOWNLOAD
0 – 1 not available
2 can esx broken
there is not any CAN bus communication with Powertronic unit. First of all check power supply of the
Powertronic unit. Then check the can bus cable from the display to the Powertronic
3 overload
Overload control active (weight lifted is bigger than maximum allowed): all movements except retraction are locked
4 bypass key
5 bypass min dist
6 bypass max angle
7 bypass overload
8 bypass buzzer
9 bypass engine
10 bypass cells
The meaning is described on the bypass chapter
11 bypass transm safety
12 bypass all safeties
The meaning is described on the bypass chapter
13 invalid calibration
The electronic system has reported some strange values from the sensor. All movements are
locked. Restart the system.
14 system reset
This message can be shown only on the black box alarms. It is happened when the service
people has forced, from the external white keyboard, a system reset in order to repeat all
calibrations
15 cmd twist lock broken
16 cmd twist unlock broken
17 cmd side shift dx broken
18 cmd side shift sx broken
19 cmd side slop dx broken
20 cmd side slop sx broken
21 cmd rot clock broken
22 cmd rot anticlock broken
EPROM memory does not have a valid parameter. Force a default parameter through
“system reset”.